EMI/RFI Shielding gaskets - Holland Shielding Systems BV EMI Shielding Solutions
Choose your language: English German Dutch
Home
About Us
Theory
Contact
Jobs
News
How to order?
Products
All Products
EMI/IP gaskets
Cable shielding
Coatings & glue
Windows/LCD
Foils and tapes
Conductive sheets
PCB shielding
Ventilation
Fingerstrips
Faraday Cages
Thermal materials
Absorbers/ferrites
Magnetic shielding
Power line filters
Clip-on gaskets
How To Shield
Displays & Windows
Faraday Cages
Racks - Enclosures
PCB - Board Level
Plastic Housing
How to test
CE Marking
FCC
Measurements
Downloads
Certificates
Datasheets
Disclaimer
EMC encyclopedia
Datasheets
Contact Us
EMI/RFI Shielding products

Low and high-frequency field strenght measurings on location

Low-frequency and high-frequency field strenght measurings on location

Electromagnetic fields cause interference with electronics or they may affect the health of human beings. It is important to recognize this at an early stage. This can be done at a future construction location as well as while construction is in progress, so that budgets are not exceeded. By means of field-strength measurements one can chart the existing electromagnetic fields and radiation emitted by, to name but a few, GSM, UMTS antennas and transformer spaces. Based on these measurements the best location may be determined for rooms where sensitive measurements are to take place, for example in hospitals or nano laboratories. And lastly, field-strength measurements can detect sources of interference and be part of a scheduled check of existing screened spaces and Faraday cages.

Magnetic field-strenght ELF-measurements

Measurements can be carried out in the low-frequency spectrum (0 Hz DC - 30 MHz ) for magnetic fields around installations through which high currents flow. In most cases the frequency is 50/60Hz, for example in transformer spaces, overhead lines, bushbar systems, switchboard cabinets and close to high-voltage cables, train and underground railway lines.

Electric field-strenght EMF-measurements

Likewise measurements can be carried out in the high-frequency spectrum (9 kHz -22 GHz) for measuring electric fields generated by transmission equipment/installations among which C2000, GSM and UMTS towers, radar systems, wireless devices etc.  

Tests may be performed to meet ICNIRP standardizations or alternative health recommendations such as SBM-2008.

Applications

  • Baseline
  • Elektromagnetic fields (V/m) or (W/m2)
  • EMF measurement
  • ELF measurement of transformer room (nano Tesla)
  • Detection of sources of interference
  • Established norms for health, environment, licenses, arbo regulations 
  • Determining location for rooms to conduct sensitive measurements
  • Check of shielded areas
  • Assessment for the opposing party
Magnetische veldsterkte meting na afscherming

Magnetic field-strenght measuring
after shielding

Elektrische veldsterkte

Electric field-strenght measuring
on location

Inhouse antenna calibratie
Inhouse antenna calibration

Field-strenght measurement 
on location

Why measure?

It is extremely complicated to approach electromagnetic radiation from a theoretical angle - it can even be said to be impossible, due to the many variables in the environment. That is why measurement on location is often essential to chart the prevailing electromagnetic fields and to localize possible sources of interference.

Advantages
  • Measurement on location
  • Cost-effective
  • Clear reporting
  • Expertise in all screening/shielding disciplines
  • Recommendations with regard to reduction of the fields
  • Certification
Prevailing fields and recommended standards

Both for magnetic and for electric fields there are recommended standards, set by the Health Council as limits in the Telecommunications Act. Particularly magnetic fields are considered a serious threat to health; for instance, there is wide-spread concern regarding the causal connection between exposure to magnetic fields and the occurrence of leukemia in children. Moreover there are numerous health complaints which are associated with (linked to) exposure to magnetic fields, for example headaches, depression and insomnia..

Opstelling reductie meting

 UMTS/GSM antenna

 

Analyse elektromagnetische meting Demping karakteristiek + calibratie meting

Electromagnetic Analysis Measurement 

Damping characteristics + measurement calibration

Determining position of sensitive measurement room

When a map is made of the existing prevailing electromagnetic fields during construction, in an existing building or during remodeling, recommendations can be made for the optimal position for a sensitive measurement room.

Inspection measurements of Faraday cages

Every Faraday cage needs regular maintenance check-ups. This does not only apply to the workmanship of the door, because there can be many invisible reasons for a cage to become ‘leaky’ so it no longer works according to specifications. To check this we carry out control measurements on location. After the measurement, a certificate is provided. Periodic measurements are important for hospitals and companies with ISO (9000) certification.

Reductie prestatie metingen 9KHz tot 22GHz Opstelling test-antenne in mu-copper afgeschermde ruimte

Reduction performance measures 9 KHz to 22 GHz

Drawing test antenna

mu-copper screened room


 



 

References:
(Below some examples of our customer portfolio)

 

Holland Shielding Systems BV performs professional Full Spectrum Magnetic DC & AC and electromagnetic EMF surveys throughout Europe and around the world.

Below you see frequency's that we can measure from low to high frequency:
(For more information regarding our measurements, please contact us.)
 
The electromagnetic spectrum
 
  > Quick menu
  > All products
  > Contact us
  > Request catalog & samples
  > Become a distributor
  > Download catalog (PDF)
  > Quick question form
  > Quick quotation form
  > Add HSS to your favorites
  > Live product chat
  > Projects
  > Official distributors

  > Download documentation
 

  > Quick product selection
Go to all products

  > On-line catalog

  > Customers